Investigation of the Effects of Different Finish Line Geometries on the Fracture Resistance and Microleakage Potential of Occlusal Veneers Using Scintigraphy
Project no. 32788 · Status: Kapanmış (Yayın bekleniyor) · 2025
Summary
<p><strong>Objective:</strong> The aim of this in vitro study was to evaluate the effect of different finish line designs on the fracture load, marginal microleakage, and failure mode distribution of lithium disilicate occlusal veneers using a scintigraphic method.</p><p><strong>Materials and Methods:</strong> Fifty extracted human mandibular molars were randomly allocated into five groups (n = 10) as non-prepared control, chamfer, knife-edge, shoulder, and butt-joint. Occlusal veneers were designed digitally and fabricated from lithium disilicate glass-ceramic using the heat-press technique, and were adhesively cemented following standardized surface treatment and cementation protocols. All specimens underwent thermocycling (10,000 cycles, 5–55 °C). Marginal microleakage was quantitatively assessed using technetium-99m–based uptake system and expressed as counts per minute (CPM). Afterwards, they were loaded to fracture by using a universal testing machine under oblique loading at 45°. Failure modes were evaluated under stereomicroscopy and SEM and classified as adhesive, cohesive, or mixed. Data were analyzed using one-way ANOVA and chi-square tests (α = 0.05).</p><p><strong>Results:</strong> No statistically significant differences were found among preparation designs for marginal microleakage (p = 0.359) or fracture load (p = 0.249). Numerically, the shoulder group exhibited the lowest mean microleakage values, while the butt-joint group showed the highest. Knife-edge preparations demonstrated the highest mean fracture load, whereas chamfer preparations showed the lowest. Cohesive and mixed failures predominated across all groups. When failure modes were regrouped into three main categories, no significant association was observed between preparation design and failure mode distribution (p = 0.167). <strong>Conclusion:</strong> Within the limitations of this <em>in vitro</em> study, finish line design did not significantly influence the fracture resistance or marginal microleakage of lithium disilicate occlusal veneers. Conservative, morphology-guided preparation designs may therefore be clinically preferable when adequate adhesive protocols are applied.</p><p><strong>Keywords:</strong> occlusal veneer; lithium disilicate; finish line design; fracture resistance; microleakage; scintigraphy.</p>