An Exergetic Performance Improvement Potential of a Modified Ejector-Enhanced Auto-Cascade Refrigeration Cycle

Makaleler > Tam Makale · 2024

Yazarlar: Arif Hepbasli, Lütfiye ALTAY, İbrahim KARAÇAYLI

International Journal of Exergy, Uluslararası, Scopus, 2024, cilt 46

DOI: 10.1504/ijex.2025.10067148

Özet

This study examines both conventional and advanced exergy analyses of a modified ejector-enhanced auto-cascade refrigeration (MEACR) cycle. Conventional exergy analysis shows that the proposed model significantly improves exergy efficiency compared to similar ejector-enhanced auto-cascade refrigeration cycles in the literature. Advanced exergy analysis reveals that 63.47% of the total exergy destruction is avoidable. When the components of the MEACR cycle are investigated, 56.31% of the exergy destruction is attributed to the endogenous part. The low-temperature cycle (LTC) compressor has the highest avoidable endogenous exergy destruction rate of 12.64 kW with 38.5%.