Damla Sulama Sistemlerinde Kullanılan Elek Filtrelerde Görülen Bazı Tasarım Hatalarının Yük Kayıpları Üzerine Etkisi
Makaleler > Tam Makale · 2003
Yazarlar: Vedat DEMİR, Hüseyin YÜRDEM
Ege Üniversitesi Ziraat Fakültesi Dergisi, Hakemli Üniversite Dergisi, Ulusal, Cab Abstracts, 2003, cilt 40, ss 81-88
Özet
<p class="MsoNormal" style="margin-bottom:6.0pt;text-align:justify;text-indent: 7.1pt"><span lang="EN-US" style="font-size:10.0pt;mso-ansi-language:EN-US">The objective of this study was to determine the effects of design faults of the domestic screen type filters used in drip irrigation systems on head losses and to provide solutions for the reducing them. In order to meet these objectives, screen filters in 2½" and 3", inlet and outlet diameters, respectively were used.<o:p></o:p></span></p><p> <span lang="EN-US" style="font-size:10.0pt;font-family:"Times New Roman","serif"; mso-fareast-font-family:"Times New Roman";mso-ansi-language:EN-US;mso-fareast-language: EN-US;mso-bidi-language:AR-SA">From the experiments conducted some design faults were discovered such as inlet and outlet area and main body diameter. With some changes on inlet and outlet area, the head losses for 2½" filter were reduced around 60% while some changes for 3" filter resulted in 40% reduction in head losses. The changes made on the body of the 3" filter body, the head losses went down about 81%.</span><br></p>