Hydrolytic Stability of Hydroxyphenyl Boronic Acids(HPBAs) and Employment of Poly(HPBAs) for Voltammetric Determination of Fluoride Levels in Dental Formulations and Beverages; Significance of Raw DPV Data for Chemometric Discrimination

Makaleler > Tam Makale · 2022

Yazarlar: Fatma Gülay DER, Görkem Yalçın, Ece Özcan Bülbül, Hakan İLERİ, Betül CİHAN, Miray GÖKCAN, Yekta Can EŞİTMEZ, Mustafa Emrah KILINÇ

Electroanalysis, SCI Expanded İndekslerine Giren Dergi, Uluslararası, Wos, 2022, cilt 34, ss 1711-1724

DOI: 10.1002/elan.202200012

Özet

Abstract Physicochemical and electrochemical properties of hydroxyphenyl boronic acids(HPBAs) and their use in fluoride determinations were investigated. HPBAs were electropolymerized at pH 1.0–11.0 in 40–60 %(v/v) methanol‐buffer. Differential pulse voltammetry(DPV) determinations of fluoride (with 1.0×10−5–1.0×10−4 M linearity based on potential shift) using poly(HPBAs) glassy carbon electrodes(GCEs) have −45.49 to +34.40 % error range. Significance of raw DPV data for chemometric discrimination was investigated by principle component analysis. This is the first demonstration of fluoride determination with poly(HPBAs)GCEs and chemometric discrimination of pharmaceutical formulations so far. Due to the lack of experimental data in literature, current findings will make a contribution to literature.

Detay görüntüle