Performance Assessment of a Near Room Temperature Magnetic Cooling System

Conference paper > Full Text ยท 2016

Authors: Orhan EKREN, Ahmet YILANCI, M. A. Ezan, M. Kara, E. Biyik

Energy Procedia, Spain, International, Verbal, Full Text, 2016-2016, Scopus, vol 107, pp 188-192

DOI: 10.1016/j.egypro.2016.12.168

Summary

In this study, performance of a near room temperature magnetic cooling system was investigated experimentally in terms of temperature span. The current setup has a permanent magnet pairs (0.7 Tesla), a magnetocaloric material (Gadolinium) and a heat transfer fluid (water, ethylene glycol and 10% ethanol-water mixing) furthermore solar energy was used as a power source of liner motion of the magnetic system. The obtained results showed that ethanol-water was the best heat transfer fluid and also that optimum magnetization-demagnetization period for the system was found 10 s.

View details