Investigation of effect of varying dead-state temperatures on energy and exergy efficiencies of a Raw Mill process in a cement plant

Makaleler > Tam Makale · 2009

Yazarlar: Ziya Sogut, Zuhal Oktay, Arif Hepbasli

International Journal of Exergy, Uluslararası, Wos, 2009, cilt 6, ss 655-655

DOI: 10.1504/ijex.2009.027495

Özet

Dead-state temperature directly affects the exergy efficiency of thermal systems. The main objectives of the present study are twofold, namely, to investigate the effects of varying dead-state temperatures on the energy and exergy analyses of a Raw Mill in a cement plant; to examine the sensitivity of the energy and exergy analyses results, calculated according to the varying dead-state temperatures. The exergy efficiency values ranged from 44.5% to 18.4% at varying dead-state temperature values between −18°C and 41°C. The sensitivity analyses results have indicated that varying dead-state temperatures have an effect on the exergy efficiency.

Detay görüntüle