Özet
<p class="MsoNormal" style="margin-bottom:0cm;margin-bottom:.0001pt;text-align: justify;text-justify:inter-ideograph;text-indent:35.4pt;line-height:150%"><b><span lang="EN-US" style="font-size:12.0pt; line-height:150%;font-family:"Times New Roman","serif";border:none;mso-ansi-language: EN-US">Aim: </span></b><span lang="EN-US" style="font-size:12.0pt;line-height: 150%;font-family:"Times New Roman","serif";border:none;mso-ansi-language:EN-US">The aim of this study was to investigate the effect of pinna position on body temperature measurements made with tympanic membrane thermometer in pediatric patients. <b><o:p></o:p></b></span></p><p class="MsoNormal" style="margin-bottom:0cm;margin-bottom:.0001pt;text-align: justify;text-justify:inter-ideograph;line-height:150%"><b><span lang="EN-US" style="font-size:12.0pt;line-height:150%;font-family: "Times New Roman","serif";border:none;mso-ansi-language:EN-US"> Materials and Methods:</span></b><span lang="EN-US" style="font-size:12.0pt;line-height:150%;font-family:"Times New Roman","serif"; border:none;mso-ansi-language:EN-US"> </span><span lang="EN-US" style="font-size: 12.0pt;line-height:150%;font-family:"Times New Roman","serif";mso-ansi-language: EN-US">The study was conducted with a quasi-experimental design with a pre-test and a post-test. For analysis of the data, frequencies, percentages, means and standard deviations were calculated, and the significance of the difference between paired values was tested in order to investigate the effects of auricle position on measurement values. <o:p></o:p></span></p><p class="MsoNormal" style="margin-bottom:0cm;margin-bottom:.0001pt;text-align: justify;text-justify:inter-ideograph;text-indent:35.4pt;line-height:150%"><b><span lang="EN-US" style="font-size:12.0pt; line-height:150%;font-family:"Times New Roman","serif";border:none;mso-ansi-language: EN-US">Results:</span></b><span lang="EN-US" style="font-size:12.0pt;line-height: 150%;font-family:"Times New Roman","serif";border:none;mso-ansi-language:EN-US"> The age of the patients included in the study ranged between 6 and 13 years, and the mean age was 10.25±1.83. The mean difference between measurements in two different positions was 0.35<sup>0</sup>C. The measurements made in each position were represented in a Bland Altman plot. It was seen that the differences between the two positions were not distributed around zero, but instead showed a systematic distribution around 0.35. There was a significant relationship between the differences and the mean values. The difference between the mean durations was found to be 1.07 seconds. The discomfort levels of the patients during temperature measurement without pinna positioning and with pinna positioning ranged between 0-2 and 0-4 according to the facial expressions scale. During temperature measurement with pinna positioning and without pinna positioning felt no discomfort.</span><span style="font-size:12.0pt;line-height:150%;font-family:"Times New Roman","serif""><o:p></o:p></span></p><p class="MsoNormal" style="margin-bottom:0cm;margin-bottom:.0001pt;text-align: justify;text-justify:inter-ideograph;text-indent:35.4pt;line-height:150%"><b><span lang="EN-US" style="font-size:12.0pt;line-height:150%;font-family:"Times New Roman","serif"; border:none;mso-ansi-language:EN-US">Conclusion: </span></b><span lang="EN-US" style="font-size:12.0pt;line-height:150%;font-family:"Times New Roman","serif"; border:none;mso-ansi-language:EN-US;mso-bidi-font-weight:bold">In measurements carried out through tympanic membrane thermometers in pediatric patients, giving position to auricle by pulling it downward posteriorly yielded more reliable and correct outcomes. <b><o:p></o:p></b></span></p><p> </p><p class="MsoNormal" style="text-align:justify;text-justify:inter-ideograph; text-indent:35.4pt;line-height:150%"><b><span lang="EN-US" style="font-size:12.0pt; line-height:150%;font-family:"Times New Roman","serif";border:none;mso-ansi-language: EN-US">Keywords: </span></b><span lang="EN-US" style="font-size:12.0pt; line-height:150%;font-family:"Times New Roman","serif";border:none;mso-ansi-language: EN-US;mso-bidi-font-style:italic">body temperature, pediatric patient, tympanic membrane thermometer, pinna position, nursing practice<i>.<o:p></o:p></i></span></p>