Exergy analyses of a tunnel furnace and a tunnel dryer

Makaleler > Tam Makale · 2021

Yazarlar: Gurhan Tahtali, Hayati OLGUN, Mustafa GÜNEŞ, ARİF HEPBAŞLI

INTERNATIONAL JOURNAL OF EXERGY, SCI Expanded İndekslerine Giren Dergi, Uluslararası, 2021, cilt 36, ss 208-208

DOI: 10.1504/ijex.2021.118717

Özet

The main objective of this study is to comprehensively perform exergy analysis of the tunnel furnace and the tunnel dryer, which was selected as the control volume and involved in a brick production line. The analysis was based on the real data measured over a one-year period at a working brick factory with a daily production capacity of 392 tons of fired bricks. Energy and exergy efficiencies of the control volume were obtained to be 76.46% and 12.90% for dead state values of 25 degrees C and 1.013 atm, respectively.